Specializing in the production of High frequency transformers&Common mode choke &SMD power inductors &Digital amplifier inductors and other magnetic components.
Specializing in manufacturing alternatives to Wurth, Sumida, Coilcraft TDK (EPCOS) transformer inductors, the price is more competitive!
Features: 1:1 transformer Double inductor with two identical windings 5 different sizes available Operating temperature: –40 ºC to +125 ºC Recommended solder profile: Reflow Custom designs on request Applicatio... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 25 mH Min DC Resistance @20 °C 3000 mΩ Max Rated Current @ 70 °C 0.3 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 15 mH Min DC Resistance @20 °C 1000 mΩ Max Rated Current @70 °C 0.5 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 8 mH Min DC Resistance @20 °C 350 mΩ Max Rated Current @ 70 °C 0.7 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) ... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 3.5 mH Min DC Resistance @20 °C 220 mΩ Max Rated Current @ 70 °C 1 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) ... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 2.8 mH Min DC Resistance @20 °C 140 mΩ Max Rated Current @ 70 °C 1.5 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 1 mH Min DC Resistance @20 °C 45 mΩ Max Rated Current @70 °C 2 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) 50 ... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 100 uH Min DC Resistance @20 °C 80 mΩ Max Rated Current @70 °C 1.5 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) ... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 47 uH Min DC Resistance @20 °C 40 mΩ Max Rated Current @ 70 °C 2 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) ... Read More
Properties Test conditions Value Unit Tolerance Inductance 10KHZ/0.25V 30 uH Min DC Resistance @20 °C 26 mΩ Max Rated Current @ 70 °C 3 A Max Rated Voltage(UR) 50 Hz 250 V/(AC) Max Insulation Test Voltage(UT) ... Read More